Description Jürgen Rose CLA 2015-07-16 06:25:30 EDT
The configuration directory is always the same when having multiple masters on one node
Comment 1 Jürgen Rose CLA 2015-07-16 06:28:29 EDT
The port for the osgi ssh console is also not correct
Comment 2 Jürgen Rose CLA 2015-07-16 06:30:19 EDT
how to reproduce:

1.) create two master server configs on one node (master1 and master2)

2.) create configuration

3.) check profile.xml of each: org.eclipse.scada.ca.file.root = ${user.home}/.eclipse.scada/ca.master

it should be ca.master1 and ca.master2
Comment 3 Jens Reimann CLA 2016-01-21 06:58:06 EST
Done.