Re: [ptp-dev] Question about performance tools framework in PTP

Wyatt
Can you clarify what you mean about the build step and where it is 
defined? My sample tools.xml file only had an execute step in it and the 
application pathname on the main tab was still disabled. What do I need to 
do or not do for this to be enabled?
Dave



Wyatt Spear <wspear@xxxxxxxxxxxxxx> 
Sent by: ptp-dev-bounces@xxxxxxxxxxx
04/19/2009 08:50 PM
Please respond to
Parallel Tools Platform general developers <ptp-dev@xxxxxxxxxxx>


To
Parallel Tools Platform general developers <ptp-dev@xxxxxxxxxxx>
cc

Subject
Re: [ptp-dev] Question about performance tools framework in PTP






Yes, I will take a look at getting more useful error output.  I will take 
a look at that specific error tomorrow as well.  I'm not sure what might 
be amiss there...

Also, regarding the program path being disabled on the main tab, the 
reason is this: For performance tools that need to be recompiled (such as 
TAU) only the build configuration is needed, so only that selection is 
available on the main tab.  If you select a tool that has no build step 
defined then it should use the normal binary selection interface on the 
main tab instead.

-Wyatt

On Sun, Apr 19, 2009 at 5:20 PM, Dave Wootton <dwootton@xxxxxxxxxx> wrote:

Wyatt 
I tried the example xml file that you included below and it failed with a 
SAXParseException. The only way I was able to figure out what was going 
wrong was to run in debug mode and catch the SAXParseException then look 
at the values for the systemID, lineNumber and columnNumber variables in 
the exception object. Those seem to point to a problem with the 
"<optvalue type="text"  fieldrequired="true"/>"  line. If I comment that 
togoption out, the exception goes away. 

Is it possible to catch the SAXParseException and write an error message 
containing the information pointing to the error either to the Error Log 
or to just print it in  a println call? 

My XML file was 


<?xml version="1.0" encoding="UTF-8"?> 
<toolset.01> 
<tool name="TaskFinder"> 
    <execute> 
        <global name="EnvironmentTest"> 
              <!--This is a static value that will always be put in the 
environment and bypass the UI entirely --> 
              <envvar flag="A_VAR" value="1"/> 

            <optionpane title="Test Vars"> 

                 <togoption label="Env Foo" optname="FOO" envvar="true"> 
                      <optvalue type="toggle" seton="yes" /> 
                </togoption> 

                <togoption label="Env Bar" optname="BAR" envvar="true"> 
                      <optvalue type="text"/> 
                </togoption> 

               <togoption label="Value Required" optname="SET_VALUE" 
envvar="true" required="true"> 
                     <optvalue type="text"  fieldrequired="true"/> 
              </togoption> 

          </optionpane> 
      </global> 
    </execute> 
</tool> 
</toolset.01> 
Dave 


Wyatt Spear <wspear@xxxxxxxxxxxxxx> 
Sent by: ptp-dev-bounces@xxxxxxxxxxx 
04/16/2009 10:00 PM


Please respond to
Parallel Tools Platform general developers <ptp-dev@xxxxxxxxxxx>


To
Parallel Tools Platform general developers <ptp-dev@xxxxxxxxxxx> 
cc

Subject
Re: [ptp-dev] Question about performance tools framework in PTP








Greetings Dave,

Environment variable support is up in cvs now.  Currently it only supports 
the execution phase and there may be a few bugs to wring out of it.  I 
believe it meets the requirements we discussed.  Note that, similar to 
program argument modifications, changes to the environment are applied 
during execution and reverted during cleanup afterward, so environment 
variables set this way will not be present in the environment pane after 
the run is complete.

I have updated the external tools wiki page with a basic reference for the 
xml tool definion format: 
http://wiki.eclipse.org/PTP/ETFw/PTP_External_Tools_Framework#Tool_XML_Reference
.


I have included a working example of environment variable usage without a 
utility tag below.  Note the use of the global tag in place of the utility 
tag.  The 'toggle' option type allows an environment variable to be 
defined as the "seton" value and left undefined if "setoff" is not 
specified.  The "required" attribute in a togoption makes it always set to 
on and does away with the checkbox.  The fieldrequired attribute in an 
optvalue tag will prevent an environment variable from being set unless 
there is a value in the widget's text field.  Please let me know if you 
would like to see any adjustments to this scheme or if you notice any 
problems. 

Regards,
Wyatt Spear

...
    <execute>
        <global name="EnvironmentTest">
              <!--This is a static value that will always be put in the 
environment and bypass the UI entirely -->
              <envvar flag="A_VAR" value="1"/>

            <optionpane title="Test Vars">

                 <togoption label="Env Foo" optname="FOO" envvar="true">
                      <optvalue type="toggle" seton="yes" />
                </togoption>

                <togoption label="Env Bar" optname="BAR" envvar="true">
                      <optvalue type="text"/>
                </togoption>

               <togoption label="Value Required" optname="SET_VALUE" 
envvar="true" required="true">
                     <optvalue type="text"  fieldrequired="true"/>
              </togoption>

          </optionpane>
      </global>
        
     </execute>
...




_______________________________________________